Q: When installing a new flexVDI Manager, a time out triggers when the progress stalls in "60 %"

A: During the flexVDI Isntaller, the 60% marks the moment when the new flexVDI Manager guest is starting, and flexvdi-config is waiting to get network connection with it.

The most common cause for a timeout in this point is that flexvdi-config network configuration has been incorrectly entered.

Please check :

  1. The network bridge associated to the fleVDI Manager has correct IP/mask/gateway configuration. It is important that the network bridg, and not the slave physical interface has the IP configuration.
  2. La IP del Manager es del mismo rango, pero distinta, a la que ha establecido en el puente de red

If the problem persists, please contact support.